| 1. Confirm the exact building site |
Match the proposed home to its actual municipality and site location. Climatic design values can vary within a region. |
NBC 2020 climatic data are location-specific; use the applicable ground snow and wind values for the site. |
Which site location and NBC climatic data were used for this home’s structural design? |
| 2. Check the ground snow load |
Ask for the NBC ground snow load value, not just a statement that the home is “built for Canadian winters.” |
Ss is the specified 1-in-50-year ground snow load, expressed in kPa. |
What Ss value was used, and is it appropriate for my exact site? |
| 3. Ask about associated rain load |
Confirm that the roof design accounts for the rain load associated with the NBC climatic data, as applicable. |
Sr is the associated rain load, expressed in kPa; it is listed separately from Ss. |
What Sr value was considered in the roof-load design? |
| 4. Verify the roof snow design |
Request the design documents for the roof, including the assumptions used for roof shape and snow exposure. |
Roof snow loading is not simply the ground snow load copied onto the roof; NBC design provisions account for applicable factors and conditions. |
Can I review the stamped structural drawings or calculations for the roof snow design? |
| 5. Look for drift and sliding-snow details |
Check roof steps, valleys, parapets, dormers, and locations where snow can accumulate or slide onto a lower roof. |
Changes in roof height and geometry can create localized snow accumulations that differ from uniform roof loading. |
Were snow-drift and sliding-snow effects assessed for this floor plan and roof configuration? |
| 6. Check the wind-pressure value |
Ask for the NBC reference wind pressure used for the site and confirm the design covers the complete building envelope. |
q1/50 is the 1-in-50 hourly wind pressure in NBC climatic data, expressed in kPa. |
What q1/50 value was used, and which site conditions were assumed? |
| 7. Review exposure and terrain assumptions |
Tell the designer if the site is open, coastal, elevated, or otherwise different from the supplier’s assumed setting. |
Wind design depends on the applicable NBC provisions and site factors; the climatic pressure alone is not the full building design pressure. |
Were exposure and topographic effects checked for my parcel? |
| 8. Inspect connections and anchorage |
Confirm the load path from roof to walls, floors, and foundation, including connections that resist wind uplift and lateral forces. |
A structural design must address how loads transfer through the building; check that the foundation and site-specific connections are included. |
Are the foundation, anchorage, and module-to-module connections engineered for this site? |
| 9. Confirm the design matches the delivered home |
Compare the approved drawings with the selected roof pitch, openings, additions, and any post-delivery modifications. |
Changes to the building geometry or structural details can affect the assumptions behind the original snow and wind design. |
Will the final drawings reflect my selected options and the actual installation site? |
| 10. Get local review and written confirmation |
Have the local authority and a qualified design professional confirm the applicable code, permits, and site-specific requirements before purchase or installation. |
Provincial and territorial adoption, amendments, permitting requirements, and site conditions can differ; NBC 2020 alone does not replace local approval. |
Who is responsible for local code review, permits, and site-specific engineering? |