| 1. Use the heaviest palletized load | Base the design check on the maximum gross unit load, including the pallet and any packaging or container that rests on the beams. | Example planning load: 800 kg per palletized unit, including its pallet. | Record the maximum expected weight, not just the average. Confirm how the rack supplier defines its rated load. |
| 2. Calculate beam-level demand | A beam-level load is commonly stated for a pair of beams. Check the total load placed on that pair and whether the rating assumes an evenly distributed load. | Two pallet positions × 800 kg = 1,600 kg on one beam level, before any separately specified allowances. | Compare the calculated level demand with the supplier’s beam-pair rating for the exact beam span and loading arrangement. |
| 3. Count every loaded beam level | Upright-frame demand depends on the loads and positions across all beam levels, along with the rack’s structural design. | Example bay: 2 pallet positions per level × 3 loaded levels × 800 kg = 4,800 kg of stored unit load per bay. | Give the supplier the complete loaded-level layout. Do not treat the bay total as a verified upright rating or divide it equally between frames without an approved calculation. |
| 4. Specify beam elevations | Upright capacity can change with frame height, beam positions, and the spacing between beam levels. The same frame may have different ratings in different configurations. | Provide each beam elevation measured from the floor, for example: 600 mm, 1,800 mm, and 3,000 mm. | Request a rating for the exact frame height and beam-level configuration, rather than relying on a rating from a different layout. |
| 5. Confirm pallet size and support | Pallet dimensions, orientation, load overhang, and the way the pallet is supported affect whether the load is suitable for the selected beams and accessories. | Example footprint: 1,200 × 1,000 mm. This is one common pallet size; other sizes and orientations are also used. | Supply pallet dimensions, orientation, load dimensions, and expected overhang. Confirm beam spacing and any required supports with the rack designer. |
| 6. Match the frame details, not just its height | Upright capacity depends on the complete frame design, including section, frame depth, bracing, connections, and component compatibility. | A frame height alone is not enough to establish a safe load rating; the frame specification and beam layout are also needed. | Request documentation that identifies the exact frame and compatible beams. Avoid combining components based only on similar dimensions. |
| 7. Include site conditions and future changes | Anchorage, floor conditions, local seismic requirements, impact exposure, and changes to beam levels or loads can affect the required design and safe use. | A layout change from 3 to 4 loaded levels changes the load configuration and requires a rating check, even if the stored weight per pallet stays the same. | Share the installation location and planned changes with a qualified rack designer. Reassess the system before changing beam positions or loading limits. |